Lessly Amaya (Cestelos)'s profile

Canyon Center School for Autism-Institutional Design

Building Data

Building Construction Type: Type III
Stories: Two
Sprinklers: Fire Supression System
Occupancy Type: I-2, I-4
Secondary Space: A-2
Square Footage: +/- 22,000 sq. ft.
Building Department: City of San Bernardino

Code and Regulation Analysis

ADA Clearances: 60” turning, 44” wide minimum
Minimum Stair Width: 44” per CBC 109.1
Minimum Exit Widths: 44” per CBC 1005.1
Minimum Exits: 2 per CBC 102.1
Corridors: Max. Length 50’
Exit Access Travel Distance: 250’ per CBC 1016.1

Plumbing Counts

First Floor:
Area W.C. Urinal Lav. W.F.
OCC Male 1 1 1 1
OCC Female 2 N.A. 1 1

Second Floor:
Area W.C. Urinal Lav. W.F.
OCC Male 1 1 1 1
OCC Female 2 N.A. 1 1
Canyon Center School for Autism-Institutional Design
Published:

Canyon Center School for Autism-Institutional Design

Institutional Interior Design for student with Autism

Published: